Agree Temperature Humidity Vibration Combined Vertical Lift Horizontal Move Chamber System
TVH Temperature/Humidity/Vibration Combined Chamber
Hardy TVH Series AGREE Vibration combined chambers offer fast temperature change rates to reduce product development time and improve product reliability. These chambers are designed for temperature, humidity & vibration combined or temperature, humidity only applications. All models can be compatibly coordinated with your choice of electrodynamic or mechanical vibration systems or other types of shakers with different structures, shapes, dimensions, parameters, also different types of removable floor plug.
AGREE chambers were originally designed for the military, defense, and aviation industries to perform temperature, humidity, and vibration tests. AGREE Environmental Chambers have been also adapted to perform reliability, qualification, and Environmental Stress Screening tests for a wide range of industries including aerospace, electronics, automotive, and telecommunications.
Standard Feature
v 1,000 to 3,000L usable test space
v -40?/-70? to 180? temperature range
v Temperature ramp rate up to 20? by mechanical cooling system
v 20%r.h. to 98%r.h. (20? to 85?) temperature/humidity range
v Performance parameters comply with IEC60068
v Front or side full open heated door with 450mmWx657mmH heated view window
v Sets of floor plugs upon requirement
v 2 sets of f100mm access ports
v 2 sets of specimen shelf
v 1 set of cascade water cooled refrigeration system utilizing R404A/R23 environmental correct refrigerant
v 2 sets of air circulation blower wheels directly driven by top mounted motors.
v 1 set of Hardy007 LCD 7" touchscreen digital field test controller(programmer/recorder) include remote controller software
v 2 sets of built in gradienters
v 1 set of 3 colors tower indicator
v 1 set of build in site power outlet(=5A)
Optional Items
v Bigger test space or even walk in vibration combined are available
v Wider temperature range up to 240? highest working temperature.
v Temperature ramp rate up to 30? by multiple mechanical or LN2 cooling system
v Specimen temperature controlling
v R404A substituted by latest environmental correct refrigerant R452A or ISCEON89
v Dry air purge system for condensate water resistance
v Upgrade to Hardy010 TFT 10" touchscreen digital field test controller
v Vertical lifting only system for combining different types of shaker
v Horizontal moving system for fixed vibration systems
v Vertical lifting & horizontal moving system for combining slip table of fixed vibration system
v Cable holding chain moving with chamber
v 1 set of build in programmable site power outlet(=5A)
v Additional shelves and access ports
Model List
Model4) | THV | 410-5/10 | 415-5/10 | 420-5/10 | 430-5 | 710-5/10/15/20 | 715-5/10/15/20 | 720-5/10/15/20 | 730-5/10/15/20 |
Test space volume | liters | 1050 | 1728 | 2160 | 3024 | 1050 | 1500 | 2160 | 3072 |
Performance for temperature tests5) | |||||||||
Temperature range | ? | -40/180 | -70/180 | ||||||
Temperature deviation in time | K | ±0.1 to ±0.5 |
|
||||||
Temperature deviation in space | K | ±0.25 to ±1.0 |
|
||||||
Temperature gradient1) | K/m | 0.5 to 2.0 |
|
||||||
Temperature ramp rate1) | K/min | 5/10 | 5 | 5/10/15/20 |
|
||||
Performance for climatic tests5) |
|
|
|||||||
Temperature range | ? | +20 to +85 |
|
||||||
Temperature deviation in time | K | ±0.1 to ±0.3 |
|
||||||
Temperature deviation in space | K | ±0.15 to ±0.5 |
|
||||||
Temperature gradient1) | K/m | 0.3 to 1.0 |
|
||||||
Humidity range | %RH | 20 to 98 |
|
||||||
Dew point range | ? | +5 to +80 |
|
||||||
Humidity deviation | %RH | ±5(=75)/+2 or -3(>75) | |||||||
Test space dimensions | W mm | 1050 | 1200 | 1200 | 1400 | 1050 | 1000 | 1200 | 1600 |
D mm | 1000 | 1200 | 1200 | 1600 | 1000 | 1200 | 1200 | 1600 | |
H mm | 1000 | 1200 | 1500 | 1350 | 1000 | 1250 | 1500 | 1200 | |
External dimensions | W mm | 3000 | 1500 | 1500 | 1700 | 1230 | 1250 | 1500 | 1900 |
D mm | 1800 | 3900 | 3900 | 4400 | 3400 | 2850 | 3900 | 4300 | |
H6) mm | NA | NA | NA | NA | NA | NA | NA | NA | |
Power supply specification2) |
|
3/N/PE, 380±10%, 50Hz |
|
||||||
Cooling of refrigeration system |
|
water cooled |
|
||||||
1) According to IEC 60068. 2) Other power specifications please consult with us. 3) Please consult with us of other CW temperature. 4) THVM refers to chamber with horizontal moving system. THVL refers to chamber with vertical lift system. THVS refers to chamber with both systems. 5) Performance data is measured at a 25? ambient temperature. 6) The hight of chamber will be influenced by the hight of shaker. |
Product Picture
- High Temperature Aging Drying Sintering Heat Treatment Oven Furnace Chamber 1 Pieces / (Min. Order)
- Altitude Low Pressure Temperature Humidity Chamber 1 Pieces / (Min. Order)
- Damper One Zone Hot Cold Air Stream Thermal Shock Chamber 1 Pieces / (Min. Order)
- Standard Panelized Full Temperature Humidity Range Walk in Chamber 1 Pieces / (Min. Order)
- ESS Environmental Stress Screening High Low Temperature Fast Change Testing Chamber 1 Pieces / (Min. Order)
- Standard Reliability Environmental Climate High Low Temperature Humidity Testing Chamber 1 Pieces / (Min. Order)