Standard Panelized Full Temperature Humidity Range Walk in Chamber
PWT(H)/SWT(H) Series Walk In Chamber
Hardy Walk-In Chambers are available in a variety of models, sizes, a wide operation range of temperature and humidity to meet virtually any requirements and/or test applications. These chambers are typically used for environmental testing or storing products even stress screening for mass specimens that require a large capacity chamber.
Hardy provides two primary types of walk-in chamber designs:
1) PWT(H)-Panelized walk-in chambers utilize panelized, thermal insulated panels that are locked together to form various size chambers or rooms.
2) SWT(H)-Welded (Solid) walk-In chambers are fully welded chambers that can withstand high temperature and high humidity along with fast temperature change rates. Welded Walk-In chambers are also ideal for test requirements with temperature higher than +150°C.
Standard Features
vFrom 5 up to 100m³ usable test space
vPWT(H): -40?/-65? to 100? temperature range
vSWT(H): -40?/-70? to 180? temperature range
vPWT(H): Temperature ramp rate up to 5? by mechanical cooling system
vSWT(H): Temperature ramp rate up to 10? by mechanical cooling system
vPWH: 20%r.h. to 95%r.h. (20? to 65?) temperature/humidity range
vSWH: 20%r.h. to 98%r.h. (20? to 85?) temperature/humidity range
vPerformance parameters comply with IEC60068
vFront full open single or bi-parting heated door with 450mmWx657mmH heated view window
v2 sets of f200mm access ports
v1 set of single stage or cascade water cooled refrigeration system utilizing R404A/R23 environmental correct refrigerant
v2 sets of air circulation blower wheels directly driven by top mounted motors.
v1 set of Hardy010 TFT 10" touchscreen digital field test controller(programmer/recorder) include remote controller software
v1 set of 3 colors tower indicator
Optional Items
vTest space can be enlarged up to =100m³
vDimensions of test space can be custom designed
vPWT(H): Max. temperature can be 150? by substitute special panel
vSWT(H): Temperature ramp rate up to 15? by multiple mechanical or LN2 cooling system
vSolid floor structure for heavy product and high temperature/humidity testing
vTracks for product cart build in the chamber floor
vManual or sliding electrical driving door
vMultiple in one test space structure used for one or multiple test in one time by different types of product.
vR404A substituted by latest environmental correct refrigerant R452A or ISCEON89
vExplosion Proof design leveled by Hazard 0-7 classes with different sets of devices
Model List
Model | PWT/PWH | 4005/7005 | 4008/7008 | 4010/7010 | 4020/7020 | 4030/7030 | 4050/7050 | 4100/7100 |
Test space volume | liters | 5400 | 8000 | 10000 | 20000 | 30000 | 50000 | 100000 |
Performance for temperature tests 4) |
|
|||||||
Temperature range | ? | -40 to 100/-65 to 100 | ||||||
Temperature deviation in time | K | ±0.1 to ±0.5 | ||||||
Temperature deviation in space5) | K | ±0.25 to ±1.0 | ||||||
Temperature gradient1) | K/m | 0.5 to 2.0 | ||||||
Temperature ramp rate1) | K/min | Up to 5 | ||||||
Performance for climatic tests 4) | PWH only |
|
||||||
Temperature range | ? | +20 to +85 | ||||||
Temperature deviation in time | K | ±0.1 to ±0.3 | ||||||
Temperature deviation in space5) | K | ±0.15 to ±0.5 | ||||||
Temperature gradient1) | K/m | 0.3 to 1.0 | ||||||
Humidity range | %RH | 20 to 95 | ||||||
Dew point range | ? | +5 to +65 | ||||||
Humidity deviation | %RH | ±5(=75)/+2 or -3(>75) | ||||||
Test space dimensions | W mm | 1500 | 2000 | 2500 | 4000 | 4000 | 5000 | 10000 |
D mm | 1800 | 2000 | 2000 | 2000 | 3000 | 4000 | 4000 | |
H mm | 2000 | 2000 | 2000 | 2500 | 2500 | 2500 | 2500 | |
External dimensions | W mm | NA | NA | NA | NA | NA | NA | NA |
D mm | NA | NA | NA | NA | NA | NA | NA | |
H mm | NA | NA | NA | NA | NA | NA | NA | |
Power supply specification2) |
|
3/N/PE, 380±10%, 50Hz | ||||||
Cooling of refrigeration system |
|
water cooled |
Model | SWT/SWH | 4005/7005 | 4008/7008 | 4010/7010 | 4020/7020 | 4030/7030 | 4050/7050 | 4100/7100 |
Test space volume | liters | 5070 | 8000 | 10000 | 20000 | 30000 | 50000 | 100000 |
Performance for temperature tests 4) |
|
|||||||
Temperature range | ? | -40 to 180/-70 to 180 | ||||||
Temperature deviation in time | K | ±0.1 to ±0.5 | ||||||
Temperature deviation in space5) | K | ±0.25 to ±1.0 | ||||||
Temperature gradient1) | K/m | 0.5 to 2.0 | ||||||
Temperature ramp rate1) | K/min | Up to 10 | ||||||
Performance for climatic tests 4) | SWH only |
|
||||||
Temperature range | ? | +20 to +85 | ||||||
Temperature deviation in time | K | ±0.1 to ±0.3 | ||||||
Temperature deviation in space5) | K | ±0.15 to ±0.5 | ||||||
Temperature gradient1) | K/m | 0.3 to 1.0 | ||||||
Humidity range | %RH | 20 to 98 | ||||||
Dew point range | ? | +5 to +80 | ||||||
Humidity deviation | %RH | ±5(=75)/+2 or -3(>75) | ||||||
Test space dimensions | W mm | 1500 | 2000 | 2500 | 4000 | 4000 | 5000 | 10000 |
D mm | 1800 | 2000 | 2000 | 2000 | 3000 | 4000 | 4000 | |
H mm | 2000 | 2000 | 2000 | 2500 | 2500 | 2500 | 2500 | |
External dimensions | W mm | NA | NA | NA | NA | NA | NA | NA |
D mm | NA | NA | NA | NA | NA | NA | NA | |
H mm | NA | NA | NA | NA | NA | NA | NA | |
Power supply specification 2) |
|
3/N/PE, 380±10%, 50Hz | ||||||
Cooling of refrigeration system |
|
water cooled | ||||||
1) According to IEC 60068. 2) Other power specifications please consult with us. 3) Please consult with us of other CW temperature. 4) Performance data is measured at a 25? ambient temperature. 5) Measured within every 2 cubic meter of test space. |
Product Picture
- High Temperature Aging Drying Sintering Heat Treatment Oven Furnace Chamber 1 Pieces / (Min. Order)
- Altitude Low Pressure Temperature Humidity Chamber 1 Pieces / (Min. Order)
- Damper One Zone Hot Cold Air Stream Thermal Shock Chamber 1 Pieces / (Min. Order)
- Agree Temperature Humidity Vibration Combined Vertical Lift Horizontal Move Chamber System 1 Pieces / (Min. Order)
- ESS Environmental Stress Screening High Low Temperature Fast Change Testing Chamber 1 Pieces / (Min. Order)
- Standard Reliability Environmental Climate High Low Temperature Humidity Testing Chamber 1 Pieces / (Min. Order)